2 m Refrigerant line for Ulisse 13 DCI
Extension line for the mobile split air conditioner Ulisse 13 DCI
This 2 m refrigerant line for the Ulisse 13 DCI is used to extend the line included in the scope of delivery. The connecting line contains copper tubes for the coolant as well as a water hose for the condensation and is suitable for units with the cooling function without heating.
Important when choosing: This 2 m line is intended for R32. Please therefore check the type plate of your Ulisse air conditioner before ordering.
2 m extension line for Ulisse 13 DCI
With the 2 m extension line, the existing line of an Ulisse 13 DCI mobile split air conditioner can be extended. This can be helpful, for example, if the line is to be routed through a wall or the positioning of the outdoor unit is to be adjusted.
The line contains the refrigerant lines made of copper as well as a water hose. This is used to transport the condensation water that accumulates inside the unit to the outside, where it is atomized by the ventilation.
Suitable for cooling without heating
The extension line is intended for Ulisse 13 DCI units with the cooling function without heating. Before ordering, you should also check which refrigerant the respective air conditioner uses.
Choose the right refrigerant – R410A or R32
Depending on the version, different refrigerants are used in Ulisse units. Newer units use R32, while other versions operate with R410A.
| Refrigerant of the air conditioner |
Suitable line |
| R32 |
R32 refrigerant line |
| R410A |
R410A refrigerant line |
R32 and R410A are not compatible. Therefore, be sure to check the type plate of the air conditioner to determine which line you need.
Routing the line through a wall
If the line is to be routed through a wall or extended, the outdoor unit must be disconnected from the line. This process is feasible with some technical understanding. Corresponding instructions are included in the scope of delivery.
If you are unsure, however, we recommend consulting an HVAC technician. If work is not carried out properly, refrigerant can escape. Work on the refrigerant line should therefore be carried out carefully and professionally.
Important when disconnecting the outdoor unit
Before disconnecting the outdoor unit, the air conditioner should have been running for a few minutes. This builds up pressure in the line so that the check valves close properly upon disconnection.
Please note: Before opening the packaging, be sure to check the type plate of your air conditioner. Opened line packages cannot be exchanged.
Technical data
| Property |
Value |
| Length |
2 m |
| Suitable for |
Ulisse 13 DCI with cooling function without heating |
| Coolant |
R32 |
| Design |
Refrigerant line with copper tubes and water hose for condensation |
Use |
Extension of the line included in the scope of delivery |
Frequently asked questions about the 2 m refrigerant line
Which air conditioner is the 2 m refrigerant line suitable for?
The line is intended as an extension for the mobile split air conditioner Ulisse 13 DCI and is suitable for units with a cooling function without heating.
How long is the extension line?
The extension line has a length of 2 meters.
Is the line suitable for R32?
Yes. The line is suitable for corresponding Ulisse units with R32.
Is the line also suitable for R410A?
No. This line is not intended for Ulisse units with R410A.
Are R32 and R410A compatible with each other?
No. R32 and R410A are not compatible with each other. The refrigerant used must be checked using the air conditioner's type plate.
What does the refrigerant line contain?
The connecting line contains copper tubes for the coolant as well as a water hose for the condensation water.
Can the line be routed through a wall?
Yes. To route it through a wall, the outdoor unit must be disconnected from the line. Corresponding instructions are included in the scope of delivery.
Can I extend the line myself?
Disconnecting the outdoor unit from the line requires technical understanding. If you are unsure, we recommend consulting an HVAC technician, as improper work can lead to the escape of refrigerant.
Why should the air conditioner run for a few minutes before disconnecting?
This builds up pressure in the line so that the check valves can close properly upon disconnection.
Can an opened line be returned?
No. Exchanging opened line packages is not possible. Therefore, be sure to check the air conditioner's type plate before opening.
Where can I see which refrigerant my Ulisse uses?
The refrigerant used is specified on the air conditioner's type plate. There you can determine whether you need an R32 or R410A line.