{"product_id":"verlaengerungsleitung-2m-zu-ulisse-13dci-mit-r32","title":"Extension cable 2 m for Ulisse 13DCI with R32","description":"\u003cstyle\u003e\n.product-description h2 {\n  color: #1170AB;\n  font-size: 2em;\n  margin-bottom: 8px;\n}\n.product-description h3 {\n  color: #1170AB;\n  margin-top: 32px;\n}\n.product-description strong {\n  color: #B61B1F;\n}\n.product-description .intro {\n  font-weight: 600;\n  font-size: 1.1em;\n  line-height: 1.6;\n  border-left: 4px solid #B61B1F;\n  padding: 12px 16px;\n  margin: 20px 0;\n}\n.product-description .highlight-box {\n  background: #f4f8fb;\n  border-left: 4px solid #1170AB;\n  padding: 16px 20px;\n  margin: 24px 0;\n  line-height: 1.6;\n}\n.product-description .features-list {\n  padding-left: 22px;\n}\n.product-description .features-list li {\n  margin-bottom: 10px;\n  line-height: 1.5;\n}\n.product-description table {\n  width: 100%;\n  border-collapse: collapse;\n  margin: 20px 0;\n}\n.product-description th,\n.product-description td {\n  padding: 11px 12px;\n  border-bottom: 1px solid #ddd;\n  text-align: left;\n  vertical-align: top;\n}\n.product-description th {\n  color: #1170AB;\n  background: #f4f8fb;\n}\n.product-description a {\n  color: #1170AB;\n  font-weight: 600;\n}\n.product-description .faq summary {\n  color: #1170AB;\n  font-weight: 700;\n  cursor: pointer;\n  padding: 12px 0;\n}\n.product-description .faq-content {\n  padding: 0 0 12px 0;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\"\u003e\n\u003ch2\u003e2 m Refrigerant line for Ulisse 13 DCI\u003c\/h2\u003e\n\n\u003cstrong\u003eExtension line for the mobile split air conditioner Ulisse 13 DCI\u003c\/strong\u003e\n\u003cp class=\"intro\"\u003eThis \u003cstrong\u003e2 m refrigerant line for the Ulisse 13 DCI\u003c\/strong\u003e is used to extend the line included in the scope of delivery. The connecting line contains \u003cstrong\u003ecopper tubes for the coolant as well as a water hose for the condensation\u003c\/strong\u003e and is suitable for units with the cooling function without heating.\u003c\/p\u003e\n\n\u003cdiv class=\"highlight-box\"\u003e\n\n\u003cstrong\u003eImportant when choosing:\u003c\/strong\u003e This 2 m line is intended for \u003cstrong\u003eR32\u003c\/strong\u003e. Please therefore check the type plate of your Ulisse air conditioner before ordering.\u003c\/div\u003e\n\n\u003ch3\u003e2 m extension line for Ulisse 13 DCI\u003c\/h3\u003e\n\n\u003cp\u003eWith the \u003cstrong\u003e2 m extension line\u003c\/strong\u003e, the existing line of an Ulisse 13 DCI mobile split air conditioner can be extended. This can be helpful, for example, if the line is to be routed through a wall or the positioning of the outdoor unit is to be adjusted.\u003c\/p\u003e\n\n\u003cp\u003eThe line contains the \u003cstrong\u003erefrigerant lines made of copper\u003c\/strong\u003e as well as a water hose. This is used to transport the condensation water that accumulates inside the unit to the outside, where it is atomized by the ventilation.\u003c\/p\u003e\n\n\u003ch3\u003eSuitable for cooling without heating\u003c\/h3\u003e\n\n\u003cp\u003eThe extension line is intended for \u003cstrong\u003eUlisse 13 DCI units with the cooling function without heating\u003c\/strong\u003e. Before ordering, you should also check which refrigerant the respective air conditioner uses.\u003c\/p\u003e\n\n\u003ch3\u003eChoose the right refrigerant – R410A or R32\u003c\/h3\u003e\n\n\u003cp\u003eDepending on the version, different refrigerants are used in Ulisse units. Newer units use \u003cstrong\u003eR32\u003c\/strong\u003e, while other versions operate with \u003cstrong\u003eR410A\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ctable\u003e\n\n\u003cthead\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRefrigerant of the air conditioner\u003c\/th\u003e\n\n\u003cth\u003eSuitable line\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eR32\u003c\/td\u003e\n\n\u003ctd\u003e\u003cstrong\u003eR32 refrigerant line\u003c\/strong\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eR410A\u003c\/td\u003e\n\n\u003ctd\u003e\u003cstrong\u003eR410A refrigerant line\u003c\/strong\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eR32 and R410A are not compatible.\u003c\/strong\u003e Therefore, be sure to check the \u003cstrong\u003etype plate of the air conditioner\u003c\/strong\u003e to determine which line you need.\u003c\/p\u003e\n\n\u003ch3\u003eRouting the line through a wall\u003c\/h3\u003e\n\n\u003cp\u003eIf the line is to be routed through a wall or extended, the \u003cstrong\u003eoutdoor unit must be disconnected from the line\u003c\/strong\u003e. This process is feasible with some technical understanding. Corresponding instructions are included in the scope of delivery.\u003c\/p\u003e\n\n\u003cp\u003eIf you are unsure, however, we recommend consulting an \u003cstrong\u003eHVAC technician\u003c\/strong\u003e. If work is not carried out properly, refrigerant can escape. Work on the refrigerant line should therefore be carried out carefully and professionally.\u003c\/p\u003e\n\n\u003ch3\u003eImportant when disconnecting the outdoor unit\u003c\/h3\u003e\n\n\u003cp\u003eBefore disconnecting the outdoor unit, the air conditioner should have been running for a few minutes. This builds up pressure in the line so that the \u003cstrong\u003echeck valves close properly upon disconnection\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cdiv class=\"highlight-box\"\u003e\n\n\u003cstrong\u003ePlease note:\u003c\/strong\u003e Before opening the packaging, be sure to check the type plate of your air conditioner. \u003cstrong\u003eOpened line packages cannot be exchanged.\u003c\/strong\u003e\u003c!-- nl--\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\n\u003ctable\u003e\n\n\u003cthead\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eProperty\u003c\/th\u003e\n\n\u003cth\u003eValue\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eLength\u003c\/td\u003e\n\n\u003ctd\u003e2 m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSuitable for\u003c\/td\u003e\n\n\u003ctd\u003eUlisse 13 DCI with cooling function without heating\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCoolant\u003c\/td\u003e\n\n\u003ctd\u003eR32\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDesign\u003c\/td\u003e\n\n\u003ctd\u003eRefrigerant line with copper tubes and water hose for condensation\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctd\u003eUse\u003c\/td\u003e\n\n\u003ctd\u003eExtension of the line included in the scope of delivery\u003c\/td\u003e\n\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\u003ch3\u003eFrequently asked questions about the 2 m refrigerant line\u003c\/h3\u003e\n\n\u003csection class=\"faq\"\u003e\n\u003cdetails class=\"faq-accordion\" open=\"\"\u003e\n\u003csummary\u003eWhich air conditioner is the 2 m refrigerant line suitable for?\u003c\/summary\u003e\n\u003cdiv class=\"faq-content\"\u003e\n\n\u003cp\u003eThe line is intended as an \u003cstrong\u003eextension for the mobile split air conditioner Ulisse 13 DCI\u003c\/strong\u003e and is suitable for units with a cooling function without heating.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c\/details\u003e\n\u003cdetails class=\"faq-accordion\" open=\"\"\u003e\n\u003csummary\u003eHow long is the extension line?\u003c\/summary\u003e\n\u003cdiv class=\"faq-content\"\u003e\n\n\u003cp\u003eThe extension line has a length of \u003cstrong\u003e2 meters\u003c\/strong\u003e.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c\/details\u003e\n\u003cdetails class=\"faq-accordion\" open=\"\"\u003e\n\u003csummary\u003eIs the line suitable for R32?\u003c\/summary\u003e\n\u003cdiv class=\"faq-content\"\u003e\n\n\u003cp\u003eYes. The line is suitable for corresponding Ulisse units with \u003cstrong\u003eR32\u003c\/strong\u003e.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c\/details\u003e\n\u003cdetails class=\"faq-accordion\" open=\"\"\u003e\n\u003csummary\u003eIs the line also suitable for R410A?\u003c\/summary\u003e\n\u003cdiv class=\"faq-content\"\u003e\n\n\u003cp\u003eNo. This line is not intended for Ulisse units with \u003cstrong\u003eR410A\u003c\/strong\u003e.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c\/details\u003e\n\u003cdetails class=\"faq-accordion\" open=\"\"\u003e\n\u003csummary\u003eAre R32 and R410A compatible with each other?\u003c\/summary\u003e\n\u003cdiv class=\"faq-content\"\u003e\n\n\u003cp\u003eNo. \u003cstrong\u003eR32 and R410A are not compatible with each other.\u003c\/strong\u003e The refrigerant used must be checked using the air conditioner's type plate.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c\/details\u003e\n\u003cdetails class=\"faq-accordion\" open=\"\"\u003e\n\u003csummary\u003eWhat does the refrigerant line contain?\u003c\/summary\u003e\n\u003cdiv class=\"faq-content\"\u003e\n\n\u003cp\u003eThe connecting line contains \u003cstrong\u003ecopper tubes for the coolant as well as a water hose for the condensation water\u003c\/strong\u003e.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c\/details\u003e\n\u003cdetails class=\"faq-accordion\" open=\"\"\u003e\n\u003csummary\u003eCan the line be routed through a wall?\u003c\/summary\u003e\n\u003cdiv class=\"faq-content\"\u003e\n\n\u003cp\u003eYes. To route it through a wall, the outdoor unit must be disconnected from the line. Corresponding instructions are included in the scope of delivery.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c\/details\u003e\n\u003cdetails class=\"faq-accordion\" open=\"\"\u003e\n\u003csummary\u003eCan I extend the line myself?\u003c\/summary\u003e\n\u003cdiv class=\"faq-content\"\u003e\n\n\u003cp\u003eDisconnecting the outdoor unit from the line requires technical understanding. If you are unsure, we recommend consulting an \u003cstrong\u003eHVAC technician\u003c\/strong\u003e, as improper work can lead to the escape of refrigerant.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c\/details\u003e\n\u003cdetails class=\"faq-accordion\" open=\"\"\u003e\n\u003csummary\u003eWhy should the air conditioner run for a few minutes before disconnecting?\u003c\/summary\u003e\n\u003cdiv class=\"faq-content\"\u003e\n\n\u003cp\u003eThis builds up pressure in the line so that the \u003cstrong\u003echeck valves can close properly upon disconnection\u003c\/strong\u003e.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c\/details\u003e\n\u003cdetails class=\"faq-accordion\" open=\"\"\u003e\n\u003csummary\u003eCan an opened line be returned?\u003c\/summary\u003e\n\u003cdiv class=\"faq-content\"\u003e\n\n\u003cp\u003eNo. \u003cstrong\u003eExchanging opened line packages is not possible\u003c\/strong\u003e. Therefore, be sure to check the air conditioner's type plate before opening.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c\/details\u003e\n\u003cdetails class=\"faq-accordion\" open=\"\"\u003e\n\u003csummary\u003eWhere can I see which refrigerant my Ulisse uses?\u003c\/summary\u003e\n\u003cdiv class=\"faq-content\"\u003e\n\n\u003cp\u003eThe refrigerant used is specified on the \u003cstrong\u003eair conditioner's type plate\u003c\/strong\u003e. There you can determine whether you need an R32 or R410A line.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c\/details\u003e\n\u003c\/section\u003e\n\u003c\/section\u003e\n","brand":"Baustore","offers":[{"title":"Default Title","offer_id":54155649745243,"sku":"9.148","price":310.0,"currency_code":"CHF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1035\/4435\/7211\/files\/ulisse-verlaengerung-R32.jpg?v=1790087965","url":"https:\/\/baustore.ch\/en\/products\/verlaengerungsleitung-2m-zu-ulisse-13dci-mit-r32","provider":"Baustore.ch","version":"1.0","type":"link"}